Skip to main content

Cold-Formed Steel Floor: Floor Joists and Diaphragm

This article covers three floor-related topics in cold-formed steel buildings: the checking of floor joists, the automatic generation of floor joists by dividing a cold-formed steel floor into strips, and the verification of the floor acting as a diaphragm that transfers earthquake and wind forces to the panels. For the general design of beams and columns see Cold-Formed Steel Beam and Column Design, and for the equations see Theoretical Basis of Cold-Formed Steel Design. The article Worked Example: Two-Storey Cold-Formed Steel Building applies all of these features step by step.

info

Which editions? Cold-formed steel calculations and the Cold-Formed Steel tabs in the Bond Beam Properties and Slab Properties windows are available in the StatiCAD Ultimate edition.

1. Floor joist checks (HCBTİE 4.8, 7.4, 7.5)​

Beams of the Cold-Formed Steel type are checked as floor joists. The Cold-Formed Steel tab in the Bond Beam Properties window contains the inputs specific to floor joists. The inputs are used only for the Cold-Formed Steel beam type; the defaults (0) are on the safe side.

InputMeaningDefault
Top flange continuously connected to sheathingIf the floor sheathing (OSB, plywood, trapezoidal sheeting) is screwed continuously to the top flange, lateral–torsional buckling does not occur under positive moment (span, top flange in compression); Md+ then comes from the local and distortional buckling rows.Off (Lb+ = member length)
Bottom flange lateral restraint spacing Lb (mm)Spacing of blocking, bridging or bottom sheathing under negative moment (support region, bottom flange in compression).0 = member length
Support typeAutomatic: if there is no column at the end and a wall is present, the joist is taken as bearing on the wall (web crippling is checked); at a column it is taken as connected through the web. Bearing or Web-connected (clip angle; no crippling check) can be selected manually.Automatic
Bearing length ss (mm)Bearing length at the support. HCBTİE 7.4(e) requires at least 40 mm; a warning is given if less is entered.0 = 40 mm
Web stiffener at supportIf declared, the 7.4 conditions are considered valid instead of web crippling; Eq. 4.8.6 is used for bending + shear.None
Load from above at supportIf an upper-storey wall or stud is present above the support (two opposing local forces), web crippling is calculated with the corresponding equation.None
Joist spacing < 40 cm and at least two rows of bridgingThe second route of HCBTİE 7.5: when the span/depth ratio exceeds 18 or the frequency is below 8 Hz, this declaration removes the vibration warning.None

With multiple selection, fields that differ among the selected beams appear undetermined (check box grey, text empty, list without selection) and are not applied unless changed. The inputs are saved with the project; projects saved before these inputs existed open with the default values.

1.1 Checks performed​

  • Signed bending: Positive (span) and negative (support) moments are enveloped separately. Each is compared with Md+ and Md−, calculated with its own lateral restraint length and Cb coefficient (AISI S100 F2.1.1, HCBTİE 1.3). Cb = 1 is taken for cantilevers and for lengths with intermediate restraint.
  • Combined bending + shear (HCBTİE 4.8.2): M and V in the same section and the same combination are taken together. In the denominator, the bending strength Mdlo, which excludes lateral–torsional buckling, is used (for a web with stiffeners, the smaller of this and the distortional strength).
  • Web crippling (HCBTİE 4.8.3): Since 4.8.3 gives no equation for the strength, it is calculated according to TS EN 1993-1-3 6.1.7.2 (HCBTİE 1.3). At an interior support (a cold-formed steel joist continuing in the same direction), the demand is the sum of the end shears on both sides. Sections with a Sigma (Σ) web and those with r/t > 6 or hw/t > 200 are outside the scope of these equations; in that case a “could not be checked” warning is given.
  • Web stiffener requirement (HCBTİE 7.4): For a plain web, an intermediate stiffener is required if h/t > 180 or V > 0.8Vd.
  • Live-load-only deflection (HCBTİE Table 7.1): The limit is L/250. It is not applied to the cantilever deflection type.
  • Vibration (HCBTİE 7.5): Span/depth ≤ 18 and the estimated natural frequency of a single-span joist ≥ 8 Hz.
note

The cold-formed steel beam page of the report contains the web crippling, web stiffener and vibration rows; the geometry, demand, bending, shear and deflection rows show signed (positive/negative moment) values. The analysis warnings report the web stiffener requirement, the vibration condition, web crippling that could not be checked, a bearing length shorter than 40 mm and, for information, the TS EN 1993-1-3 6.1.11 moment + local force interaction. The automatic support type relies on the adjacency of a column and a wall at the end. If adjacency is not recognised (e.g. in some cold-formed steel columns with polygonal sections), the beam is treated as a cantilever (Cb = 1) and crippling is not checked; in that case select Bearing as the support type manually.

2. Cold-formed steel floor: strips and floor joists​

To convert a rectangular slab into a cold-formed steel floor, use the Cold-Formed Steel tab of the Slab Properties window (the inputs are enabled only when a single drawn slab is being edited; while a slab is being defined, the tab only describes these steps):

  1. Tick the Cold-formed steel floor box; enter the floor joist section (from the predefined profile list, e.g. CC C200x80x16x2), the material (blank = S235), the maximum joist spacing (mm), the joist direction (parallel to the X or Y axis), the sheathing type and the bridging declaration.
  2. Tick Generate / refresh strips and floor joists on OK and press OK.

The program divides the span equally so that the given spacing is not exceeded (e.g. 4.0 m and 400 mm → 10 spaces, 9 joists). The joists are generated as Cold-Formed Steel type bond beams: both ends M2 + M3 hinged, top flange connected to the sheathing (Chapter 1), and the sheathing type and joist spacing assigned for the rotational restraint (kφ) of the sheathing. The slab is divided between the joists into strips carrying the same properties (thickness, G, Q, material); the strips and joists are collected in the selection group of the slab (if there is no group, one is created with the slab name).

  • Regeneration: Change the definition in the Cold-Formed Steel tab of any strip and confirm with generate / refresh; the strips in the same group and the generated joists are deleted, the original slab is rebuilt and divided with the new definition.
  • Undo: Clear the Cold-formed steel floor box and confirm with generate / refresh; the original slab returns and the generated joists are deleted.
  • Geometry: The two edges parallel to the joists must be parallel to an axis (the bottom and top edges for the X direction, the left and right edges for the Y direction); the other two edges may be inclined. Polygonal (shell) slabs are not supported.
  • Load: For the joists to receive load width × G/Q, classical load transfer and “slabs not included in system stiffness” are recommended in the Project General Settings. With shell transfer, or when slabs are included in the stiffness, the strips share load between the joists; if the edge joists are flexible, load shifts to the joists near the columns and the analysis gives a warning.
note

If a definition has been made but the strips and joists have not been generated, the analysis gives a warning. End hinges defined on steel and cold-formed steel beams are applied in the finite element solution; the generated floor joists behave as simple beams.

tip

Place a cold-formed steel header (lintel) at every door and window opening where floor joists end; otherwise that end of the joist is left unsupported, the finite element solution gives a singular stiffness warning and the joists turn out inadequate.

3. Cold-formed steel floor diaphragm (TBDY 10.5 / HCBTİE 7.4)​

At every floor level that has a cold-formed steel floor definition (Chapter 2), the analysis checks that the floor, acting as a diaphragm, transfers earthquake and wind forces to the vertical panels. The inputs are in the Floor diaphragm group at the bottom of the Slab Properties › Cold-Formed Steel tab (0 = default):

  • Sheathing unit shear strength vn (kN/m): The code gives no value for floors. If left 0, the wall panel value in TBDY Table 10.5 is used by analogy (11 mm OSB 10.2, 12 mm plywood 11.4 kN/m); no sheathing check is made for gypsum board or undefined sheathing. Enter a test value (TBDY Annex 10.C) or the manufacturer’s value.
  • Floor → lower panel top track screw: Diameter and spacing (0 → 4.8 mm / 300 mm), and optionally the manufacturer’s screw shear strength Pnvs.

A change made in one strip is propagated to all strips of the family on OK (even if generate / refresh is not ticked). The following are checked:

  1. Wall line force (TBDY 4.5.6.4, with D): The lower- and upper-storey panels in the same direction and within 20 cm form a line; F = top-section shear of the lower-storey panels − bottom-section shear of the upper-storey panels.
  2. Sheathing unit shear: v = F/B (B: floor depth along the line, TBDY Figure 10.11) ≤ φ·vn (earthquake 0.60 / Ω 2.5; wind 0.65 / 2.0).
  3. Collector (longitudinal transfer element): Axial force along the line; it increases if the wall does not cover the whole line or if the upper and lower walls are offset. It is compared with the tensile and compression strength of the floor joist section; the number of screws required for the splice is reported.
  4. Floor → lower panel connection: Top-section shear of the lower-storey panel (with D) ≤ n·Ps (TBDY 10.3.4). The upper-storey panel → floor connection is in the panel anchor table (shear anchor type “screw”).
  5. Chord force: T = C = F·L/(8·B) in each floor family; it is compared with the tensile and compression strength of the floor joist section, and the number of screws required for the splice is reported.
  6. Opening: If the opening area exceeds 3% of the floor area, the floor must be modelled as a shell element (semi-rigid diaphragm) (HCBTİE 7.4(d)); the ratio is calculated when the irregularity checks are on.

Compression in the collector and chord: Since the diaphragm force changes sign with the direction of the earthquake and wind, the collector and chord forces must be carried both in tension and in compression. The compression strength Pd is the compression strength of the floor joist section found with EWM; the buckling length is the floor joist spacing (the maximum joist spacing in Chapter 2; 400 mm if not entered). The report shows “Td = …, Pd = … (Lb = …)” and, for the splice, “ek yeri ≥ n vida” (splice ≥ n screws); since the position of the splice is not known, the number of screws is given for the largest force. In a collector portion spanning an opening, with no wall below it, the strong-axis buckling length equals the opening width; check this portion separately.

note

The results appear in the report under the heading Cold-formed steel floor diaphragm at the end of the cold-formed steel beam design section (if floor joists have been generated), the level summaries on the floor diaphragm page, the inadequacies in the analysis warnings and the project checklist (TBDY 10.5 / HCBTİE 7.4). At levels where all slabs are cold-formed steel, the reinforced concrete floor diaphragm checks (TBDY M.7.11) are not performed.

4. Beam axis offset and composite axial force​

If Take Offset1 and Offset2 values into account in the system stiffness matrix or, with a defined axis, Take eccentricities into account in the system stiffness matrix is ticked in the Project General Settings, the beam axis is modelled below the node axis. Because the rigid diaphragm or the supports restrain the axial displacement of the nodes, the section behaves like a composite section working with an infinitely rigid flange and receives an axial force that does not exist in reality.

In cold-formed steel beam design, as for reinforced concrete beams, the program subtracts this share from the axial force of each load case; the moment is unchanged, i.e. the section carries the total moment without the composite contribution. It is therefore not necessary to clear the offset boxes. The state of the Offset1 and Offset2 box is saved with the project; older projects that do not contain this information open with the box ticked. The raw axial force continues to appear in the finite element beam result tables. The same correction is also applied to heavy (hot-rolled) steel beams. For the equations, see the article Theoretical Basis.

5. Frequently asked questions​

I get a “web crippling could not be checked” warning on a floor joist. The section is outside the scope of the TS EN 1993-1-3 6.1.7.2 equations (Sigma web, r/t > 6 or hw/t > 200). Select a C, Z, U or C+ section, or declare a web stiffener at the support.

Web crippling is not calculated at all on a floor joist. With the automatic support type, the joist may have been taken as “web-connected” because there is a column at the end, or end adjacency may not have been recognised. If the joist bears on a wall, select Bearing as the support type in the Cold-Formed Steel tab.

How do I remove the vibration warning? HCBTİE 7.5 requires span/depth ≤ 18 and natural frequency ≥ 8 Hz. Select a deeper section, reduce the span, or reduce the joist spacing below 40 cm, provide at least two rows of bridging and tick this declaration.

The moments of the generated floor joists differ greatly from one another. If the slabs participate in the system stiffness as shells, the sheathing shares load between joists; if the edge joists are flexible, load shifts to the joists near the columns. For design by load width, select classical load transfer in the Project General Settings and do not include the slabs in the system stiffness.

The diaphragm sheathing check turns out inadequate. The default vn value is taken by analogy from the wall panel table. For diaphragms with blocking or close edge screw spacing, enter a test or manufacturer value in the Floor diaphragm group; if the connection is inadequate, reduce the screw spacing.