Precast Connection Design (TBDY Chapter 8)
In precast buildings, connections are designed in the Macros → Precast connection design (TBDY Chapter 8)... window. Each calculation creates a record that goes into the report. For the modeling steps, see the article Modeling Precast Structures. The design of column corbels according to TS 500 Clause 8.4 is described in the article Short Corbel Design; the corbel results also go into the same report page (Section 4).
1. Connection design window
The window has five tabs. The input boxes come filled with example values; enter the values of your own project or take them from the analysis (Section 2).
| Tab | Main inputs | Checks |
|---|---|---|
| Pinned (MFB) | Connection mass, spectral acceleration, D, R/I; beam self-weight and loads carried on top (purlin, roofing, snow), centre of gravity and purlin bearing height; bearing vertical load; bearing width and dowel–edge distance; dowel bar yield strength; beam axial force; number and diameter of dowels, concrete strength; dowel centre–edge distance | Overturning (TBDY 8.3.2) → dowel bar; dowel shear (Eq. 8.2); dowel centre–edge/diameter ratio > 6 |
| Wet on Top – Welded at Bottom (MAB3) | Height, cover, web width; negative and positive moment envelopes (without D) and envelopes with D for the weld; material strengths and coefficients; number/diameter of welded bars, plate thickness, weld thickness (0 = suggestion); provided top/bottom reinforcement; stirrups in the 2h region | Top continuity reinforcement, bottom reinforcement and bottom ≥ top/2 (7.4.2.3), weld area and length, horizontal shear dowels, MRd− ≥ Md− and MRd+ ≥ γR·Md+ (TBDY 8.4.4) |
| Purlin / Gutter Beam Connections | Connection axial force, D; dowel diameter, yield strength, friction coefficient (1.0 when grout-filled); number, thickness and length of weld seams; purlin modulus of elasticity, weak-axis moment of inertia, buckling length | Dowel shear–friction (TS 500 8.1.7), fillet weld, purlin buckling |
| Façade Panel (Chapter 6) | Panel mass, Be / Re (TBDY Table 6.1), building R/I, period, reduced displacement of the connection floor, building importance factor, SDS; hanging-type connection option | Equivalent seismic load (Eq. 6.1–6.2), lower limit (Eq. 6.5), vertical ±0.3·me·I·SDS·g, 1.4W for hanging type |
| Foundation Sliding (16.8.4) | Horizontal force, minimum vertical force (0.9G − E), friction coefficient (TBDY Table 16.3), coefficients, passive resistance (0 = neglected) | Vth ≤ Rth + 0.3·Rpt |
2. Taking demands from the analysis
The MFB, MAB3 and Purlin/Gutter Beam tabs have a Take from selected beam (analysis result) button and a Left end / Right end selector. After the analysis, select a single beam in the model and press the button; the forces at the selected end of the beam are read load case by load case (G, Q, earthquake; and the crane load cases as well if a crane is defined) and fill the boxes:
- MFB: connection mass, total G load of the beam, bearing vertical load and the maximum axial force of the seismic load cases (reduced; D is applied in the window).
- MAB3: moment demands without D from the combination envelope and weld demands magnified by D for the seismic effect (with D̄lower in the lower part); height and width from the beam section.
- Purlin/Gutter Beam: the maximum axial force of the seismic load cases.
Each Calculate button writes the result into the text area at the bottom of the window and adds a row, with type and member name, to the connection record list; if it is recalculated with the same type and name, the record is updated. The records are stored with the project and feed the connection page in the report. The input values of the window are not saved; only the calculation records are stored.
Rigid diaphragm note: In a rigid roof diaphragm, the seismic axial force of a pinned roof beam comes out as zero (the inertia of the roof mass is carried by the diaphragm). A meaningful axial force for the dowel shear must be entered from the semi-rigid (Annex 8B braced) model or from a hand calculation.
MFB tension lever arm: The program takes the lever arm of the overturning tension force according to TBDY Figure 8.1; this approach is on the safe side.
3. Reinforcement design of polygonal and nonprismatic beams
The reinforcement of reinforced concrete beams with polygon, precast-template and nonprismatic sections is calculated automatically in the analysis; the moment capacity and shear checks are also carried out:
- Flexure: Uniaxial flexure is calculated under N = 0; the required tension reinforcement is found by the bisection method from the moment capacity relation so that Mr(As) = Md (compression reinforcement is neglected, on the safe side; the upper limit is 4% of the section area). For negative moment the tension is in the top rows and the compression is in the bottom zone. In a nonprismatic section, three design sections are used: left end, mid-span (ℓn/2) and right end; six cases are calculated (two supports and the span, two directions).
- Minimum reinforcement: 0.8·fctd/fyd·bw·d and the TBDY 7.4.3.1 / 7.4.2.3 ratios; bw is the narrowest web width over the section height (in I, U and box sections the web is found automatically).
- Reinforcement selection is the same as the program’s beam workflow (straight and bent-up bars, assembly bars, support additions, web reinforcement); the results go to the detailing drawing, the quantity takeoff and the report. In a prismatic polygon whose reinforcement layout is not defined, the layout is generated automatically.
- Moment capacity Mr: Calculated at six positions (both supports top/bottom, span bottom/top) with the actual section outline and the selected reinforcement, using the TS 500 equivalent rectangular stress block; if the design moment exceeds Mr, an error is written.
- Shear and stirrups: The same method as for rectangular beams is used: with high and mixed ductility, the capacity shear Ve = Vdy + (Mpi + Mpj)/ℓn (Mp = 1.4·Mr); with limited ductility, Vd. The confinement zone is calculated with the less favourable of the end sections, the middle zone with the span section. Checks: V ≤ 0.85·bw·d·√fck (with limited ductility also Vd ≤ 0.22·bw·d·fcd), Vr ≥ Ve, stirrup spacing ≥ 50 mm.
- Stirrup layout and quantity takeoff: hmax is the larger of the two end sections (the section height in a prismatic beam). At each end there is a confinement zone of length 2·hmax (the first stirrup 5 cm from the face), and the middle zone is ℓn − 4·hmax − 10 cm (the same as for rectangular beams); if ℓn < 4·hmax + 10 cm, the whole length is made denser with the confinement spacing. In a nonprismatic section the stirrup length is calculated with h(x) at the location of each stirrup; the stirrup length in the quantity takeoff is the average of these lengths. The minimum reinforcement of the supports is calculated from their own end section.
- Drawing: In the beam cross-section drawings, the actual section outline, the cover contour and the reinforcement points are drawn instead of a rectangle. In the detailing drawing of a nonprismatic beam, the bottom edge is a broken line along the profile; the stirrups are drawn with the depth at their location and the bottom straight bar parallel to the bottom edge; the section view is generated at the station where section mark A-A is placed. A step-by-step description is in the article Defining a Nonprismatic Beam.
4. Reporting
In the tree on the Report Selection → Report tab, under the Foundation Calculations group, there is the “Precast Connection Design (TBDY Chapter 8)” page; if the project has connection records or short corbels, it comes checked by default. The page is printed when the Foundation Calculations group or only this page is checked. For each record the page contains a Type / Member (end) / Demand / Capacity / Ratio / Result row and explanatory lines that summarize the inputs and intermediate results; at the end of the page the sources of demand and capacity are written as footnotes. The report is produced in Turkish or English according to the program language setting. The project must be saved before the report is generated. Short corbels appear on this page as KONSOL rows after the connection rows (see Short Corbel Design).
5. Scope limits
- The S, H and Hd load cases are not included in the envelope in connection demands; the crane combinations and the KG in the earthquake combinations are included in the envelope.
- For polygon and nonprismatic beams, Mr does not take into account the intermediate (web) reinforcement of the section (the same assumption as for rectangular beams). In the detailing drawing of a nonprismatic beam, the section view is drawn at a single station (the location of mark A-A). In the stirrup quantity takeoff each stirrup is calculated with the beam height at its location; when the Multiple stirrups option is on, the takeoff is made with the height of the span section.
- Socket foundation and erection-stage checks are out of scope. Short corbel design is described in a separate article (Short Corbel Design).
6. Frequently encountered situations
| Symptom | Solution |
|---|---|
| “Take from selected beam” does not fill the boxes. | The analysis is not complete or a single beam is not selected in the model. Run the analysis and select only the relevant beam. |
| The dowel shear demand is zero in MFB. | In a rigid diaphragm, the seismic axial force of a pinned roof beam is zero. Enter the axial force from the semi-rigid model or from a hand calculation. |
| The connection page does not appear in the report. | There is no connection record or short corbel, the page is not checked in Report Selection, or the project is not saved. Make sure the report templates are up to date. |