Skip to main content

Theoretical Basis of Isolated Footings

This article summarises the code clauses, formulas and implementation decisions on which the StatiCAD isolated footing calculation is based. Units: kN, m, kN/m² (soil), kNm; material MPa; reinforcement mm, mm². For use see Isolated Footing Design, and for verification studies see Isolated Footing Verification Studies.

info

Sources: TS 500:2000 Cl. 3, 7, 8.1, 8.3.1, 9.1, 10.1, 10.3; TBDY 2018 4.10.3, 16.7–16.8; textbook Chapter 12 "Foundations" (Eq. 16.8a correction factors).

1. Actions and combinations​

  • The forces acting on the footing are the load case (loading) results at the lower end of the first-storey column: N (compression +), MX, MY and VX, VY in the footing local axes. MX produces eccentricity in the x direction (ex = MX / N; if +, the pressure on the +x edge increases).
  • If the column is drawn eccentric in the FEM, the force acts at the FEM node; moments are moved to the section centre: M′ = M + N·(xnode − xsection).
  • Design combinations are the combinations in the project. Horizontal earthquake load cases are magnified by max(1; 0.6·D) according to TBDY 4.10.3 (D in a light steel building). In addition the service combination G+Q is set up.
  • Footing and backfill weight with the G factor of the combination: Wf = γb·A·H (γb = 25 kN/m³), backfill Wd = γd·(Df − H)·(A − Acolumn).
  • Base forces: Nt = N + kG(Wf + Wd), MXb = MX + VX·H + N·xk (xk: distance of the column section centre from the footing centre).

2. Soil pressure (K and Y solutions: rigid footing)​

  • The footing is rigid, the soil pressure is linear and takes no tension (TS 500 10.3.1).
  • Full contact (6|ex|/Bx + 6|ey|/By ≤ 1): σ = Nt/A ± MXb·x/Iy ± MYb·y/Ix.
  • Partial contact: the pair (n angle, t) of the plane σ = k·max(0, n·p − t) that satisfies the equilibrium of Nt, ex, ey is found numerically (exact polygon clipping and integration). If the resultant falls outside the base, overturning (full uplift) is reported.

3. Soil pressure (S solution: shell + Winkler)​

  • The footing base is divided with quadrilateral shells (mesh size ≤ agboyu, 0 = 25 cm; 8–60 cells per direction). The break lines pass through the footing edges, the column faces, the section centre and the column FEM node. The cells in the column projection are E × 100 (rigid zone).
  • At each node a vertical Winkler spring ki = ks·Ai (Ai: node tributary area); horizontal and torsional degrees of freedom are restrained. The shell material is Ec = 3250√fck + 14000 MPa, ν = 0.2; no weight or mass is given to the shell.
  • After each load case solution the node pressures pi = ks·(−Uz,i) are taken and assumed uniform in the tributary rectangle.
  • Equilibrium check: Σ Fi·xi = MX + Σ Fi·xnode (also for y). The vertical residual Σ Fi − N (half of the column self-weight lumped at the base node) is accepted at the node and added to the design N. In a load case that does not satisfy equilibrium the rigid linear distribution is used.
  • In combinations the node pressures are summed linearly with the same factors; the horizontal force × H moment is added with the linear distribution; the footing and backfill weight is uniform pressure (a uniform load on a Winkler plate produces no bending).
  • In the FEM modal calculation the S footing is represented by rigid equivalent Y springs.
  • Compression-only soil. If there is tension in the combination field (including weight), the footing is solved again locally in the same mesh. Plate: ACM rectangular thin plate elements (node degrees of freedom w, ∂w/∂x, ∂w/∂y; D × 100 in the column projection), node springs ki = ks·Ai. Load: the resultant of the field at the column node Fz = Σ piAi, Mx = Σ piAi(xi − xd), My = Σ piAi(yi − yd) and the uniform footing + backfill weight. Active set iteration: the spring of a node whose settlement falls below zero (uplift) is removed, and one that returns to compression is put back; until the contact set no longer changes (at most 60 solutions; since the problem is convex the solution is unique). The total pressure at an uplifted node is zero. If the equilibrium of the result (Σ piAi = Fz + q·A, moments) is not within 10⁻⁶, the linear field is used and a warning is given. Combination forces do not change (the usual assumption of isolated footing design: redistribution of the superstructure is not taken).

4. Y solution spring coefficients​

kz = ks·A, kθX = ks·(Ixx cos²α + Iyy sin²α), kθY = ks·(Ixx sin²α + Iyy cos²α)

Ixx = BxBy³/12, Iyy = ByBx³/12, α is the footing angle. These values are about the footing centre. The footing is connected to the FEM base node of the column as a rigid body; horizontal translation and torsion are restrained. If the node is eccentric from the footing centre (if the column is drawn from the edge or the footing is placed eccentrically) or if the rectangular footing is rotated, the spring at the node is not diagonal but a full 3×3 matrix. Since the settlement of the base point is w = Uz + θX·Y − θY·X (X, Y: position of the point relative to the node), K = ks∫[1, Y, −X]T[1, Y, −X] dA:

Kzz = kz, KzθX = kz·dy, KzθY = −kz·dx, KθXθX = kθX + kz·dy², KθYθY = kθY + kz·dx², KθXθY = −ks·(Ixy + A·dx·dy)

(dx, dy) = footing centre − node; Ixy = (Iyy − Ixx)·sinα·cosα. If there is no eccentricity and the footing is square or not rotated, the matrix is diagonal (the values above). If only the diagonal were used while the node is off-centre, the coupling between vertical load and rotation and the rotational stiffness arising from the eccentricity (kz·d²) would be left out. In the SAP2000 export the same matrix is given as a coupled point spring.

5. Soil check (TBDY 16.7–16.8)​

  • Factored / earthquake combinations: qmax ≤ qt = qk/γRv, γRv = 1.4. Optionally the effective area qo = Nt/((Bx − 2|ex|)(By − 2|ey|)).
  • Service combination: qmax ≤ σem.
  • If qk is not given by hand and c′ or φ′ is given, it is computed per combination with Eq. 16.8a: the bearing capacity factors Nc, Nq, Nγ and the shape (sc = 1 + (B/L)(Nq/Nc), sq = 1 + (B/L)tanφ, sγ = 1 − 0.4B/L), depth (k = Df/B or arctan(Df/B)), inclined load (m = (2 + B/L)/(1 + B/L)), ground slope and base slope corrections; submerged unit weight below the groundwater table.
  • Sliding (TBDY 16.8.4): Vth ≤ Rth + 0.3 Rpt, drained Rth = Nt·tanδ/γRh (tanδ default 0.6; γRh = 1.1), undrained Rth = Ac·cu/γRh.

6. Section forces and reinforcement (TS 500 10.3)​

  • The critical section is the column face. The design pressure acting on the free body beyond the section (soil pressure − uniform weight) is summed with an exact polygon integral: face moment and shear. A negative face moment gives top reinforcement.
  • Shear: Vd ≤ Vcr = 0.65·fctd·b·d; upper limit Vd ≤ 0.22·fcd·b·d.
  • Punching shear (TS 500 8.3.1): Vpd = N − Fa ≤ Vpr = γ·fctd·up·d (Fa: design pressure inside the punching perimeter). The perimeter is d/2 from the column face; for a rectangular column γ = 1/(1 + 1.5(ex + ey)/√(bxby)), for a circle γ = 1/(1 + 2e/(d + D)); eccentricity e = Md/Nd.
  • Flexural reinforcement in each direction; minimum ratio 0.002 (default b·H), spacing ≤ 250 mm; diameter from the candidates of the Reinforcement Selection window. Bottom layer x bars: dX = H − cover − ØX/2, dY = H − cover − ØX − ØY/2.
  • Minimum dimensions (TS 500 10.3.2): plan dimension ≥ 0.7 m, area ≥ 1.0 m², thickness ≥ 250 mm and ≥ cantilever/4.
  • Development of column starter bars (TS 500 9.1): lb = 0.12(fyd/fctd)Ø ≥ 20Ø; available length H − cover − ØX − ØY.

7. Tie beams (TBDY 16.8.5)​

  • Axial force Nb = 0.10·SDS·Nk (Nk: the largest axial force of the columns at its ends in the footing design combinations).
  • In tension only steel (Nb/fyd, equal on two faces); in compression Nb ≤ 0.85·fcd·Ac.
  • Self-weight (1.4G) on a span fixed at both ends: support qL²/12, span qL²/24; reinforcement Nb/(2fyd) + M/(0.9·d·fyd), at least 0.5% of gross; minimum section 300 × 300, stirrups Ø8/200.

8. Calculation assumptions​

  • Punching eccentricity e = Md/Nd; the 0.4 coefficient in TS 500 Figure 8.3 belongs to the intermediate storey of a flat slab without beams.
  • fctk from TS 500 Table 3.2; for a class not in the table 0.35√fck.
  • Design pressure = soil pressure − uniform weight (the same as the net pressure in full contact; in partial contact the weight stays in its real place).
  • Y and S springs are linear in the global analysis (they take tension): because combinations are linear sums of load cases, nonlinear contact is not carried into the global model. In the design the soil takes no tension (K/Y rigid partial contact, S compression-only local plate solution). There is no horizontal soil spring; in pushover analysis the base is fixed.
  • In a mixed foundation (strip + isolated) the classical calculation takes the columns on the strip footing as fixed. In the combined structure–foundation analysis the strip nodes are held by vertical soil springs; the rotational resistance of the soil about the strip axis (ks·b³/12 per unit length) is added as a rotational spring to both ends of each foundation beam piece: k = ks·b³/12·L/2, global Rx–Ry block k·e·eT (e: plan unit vector of the piece axis); except for nodes in the isolated footing outline. In a narrow strip this resistance is small and the column on the strip behaves nearly pinned in this direction; because the fixed assumption of the classical calculation may find the earthquake forces of isolated footings low, the program gives a warning for the classical calculation in a mixed project.
  • In the combined analysis, the strip footing and tie beam nodes inside the base outline of an isolated footing are connected to the footing with a rigid link bar (to the column base node in the classical and soil springs solutions, to the nearest shell node in the shell solution); the soil springs of these nodes are removed. The design forces of the connected footing (N, MX, MY) are taken in each load case from the total finite element reaction of the footing (classical: support reaction; soil springs: 3 × 3 spring force; shell: resultant of the node springs), horizontal forces from the column. In scaled load cases that do not pass through the finite element solution (for example vertical earthquake Ez = (2/3)·SDS·G) the reaction is scaled with the same factor. A footing without a link is designed with the forces at the lower end of the column.